Product Search
Product Group | Name | Type | Application | Data Sheet |
---|---|---|---|---|
PVC Energy cables | H05V-U (YSe) | PVC Insulated wire, single core | For fixed and protected installation within appliances as well as in and on luminaires. Permissible for installation in conduitson and under plaster but only for control and signal circuits. | Download |
PVC Energy cables | H05V-K (YSf) | PVC insulated wire, fine core | For fixed and protected installation within appliances as well as in and on luminaires. Permissible for installation in conduits on and under plaster but only for control and signal circuits. | Download |
PVC Energy cables | H07V-U (Ye) | PVC Insulated wire, single core | For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. | Download |
PVC Energy cables | H07V-R (Ym) | PVC Insulated wire, stranded | For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. | Download |
PVC Energy cables | H07V-K (Yf) | PVC Insulated wire, fine core | For fixed installation in conduits on or under plaster. Suitable for protected installation. | Download |
PVC Energy cables | H03VV-F (YML) | PVC flexible cable, light-duty | Suitable for low mechanical stress in households and offices as well for household appliances. Not suitable for outdoor installation, in commercial establishments or for the connection of commercially used power tools. | Download |
PVC Energy cables | H05VV-F (YMM) | PVC Control cable, medium duty | Suitable for medium mechanical stress in households and offices as well for household appliances (also in damp rooms). Not suitable for outdoor installation, in commercial establishments or for the connection of commercially used power tools. | Download |
PVC Energy cables | AT-H05VV-U or -R (YM) | Installation cable | For fixed installation in dry and damp premises. Not suitable for unprotected installation in the open air or directly in tamped concrete. | Download |
PVC Energy cables | NYM-J or -O | PVC installation cable | For the fixed installation in dry and damp premises. Not suitable for unprotected installation in the open air or directly in tamped concrete. | Download |
Rubber energy cables | H05RR-F (GML) | Light rubber flexible cable | For use with light to moderate mechanical stressing in households and office premises for light electrical equipment. Not suitable for continuous use in the open air or for use in premises used industrially. | Download |
Rubber energy cables | H01N2-D (NSLFFöu) | Rubber welding cable | Singel core cable for connection to electrofusion units as handheld electrode cable or as ground cable for use in dry, damp rooms and outdoors. H01N2-E (finest wire) on request. | Download |
Rubber energy cables | H07RN-F (GMSuö) | Heavy flexible cable, oil resistant | Usable under medium to heavy mechanical stress in dry and wet rooms, in in free ambient or rooms subject to explosion hazards. Permissible for fixed installation on hoisting equipments, machinery etc. and for rated voltages up to 1000 V if installed protected in tubes or inside of devices and as motor power supply cable. | Download |
Rubber energy cables | NSGAFÖU (Ghuöf) | Special rubber cable, single core | For application in busses and railborn vehicles, in dry rooms, if used in distribution or switching appliances up to 1000 V, it is considered to be short circuit proof. | Download |
Control and Electronics Cables | YSLY-OZ or -OZ | PVC Control cable, unscreened | For the electrical interconnection of components of production facilities and machine tools. Limited resistant against universal mineral oil and not intended for permanent use submerged in oil. This cable is intended for indoor use and should be installed mechanically protected. | Download |
Control and Electronics Cables | YSLY-JB or -OB | PVC Control cable, unscreened | For the electrical connection of components of production machines and machine tools. Shows some resistance to all-purpose mineral oil and is not designed for permanent usage in oil baths. The cable is designed for use in buildings and should be installed with mechanical protection. | Download |
Control and Electronics Cables | YSLCY-JZ or -OZ | PVC Control cable, screened | For the electrical connection of components of production machines and machine tools if a certain level of electronic screening is required. Shows some resistance to all purpose mineral oil and is not designed for permanent useage in oil baths. This cable is designed for use within buildings and should be installed with mechanical protection.. | Download |
Control and Electronics Cables | YSLYCY-JZ or -OZ 600 | PVC control cable, oil resistant, screened | Flexible power, process control and instrumentation cable for industry and machinery environment with specific EMC (electromagnetic compatibility) requirements. The cable is resistant to UV-irradiation, to most commonly used chemicals and to oil and grease. For indoor and outdoor application. | Download |
Control and Electronics Cables | 2YSL(St)CY-J 0,6/1 kV EMV | PE/PVC motor power supply cable, screened | Double screened 2YSL(St)CY-J cables were designed as supply and connecting cables, for medium mechanical stress, fixed installation and occasionally non-guided movements, in dry, damp and wet rooms. UV-resistant black sheath is designed for outdoor applications. Double screening considerably improves electromagnetic compatibility (EMC) in buildings and plants. | Download |
Control and Electronics Cables | H05VV5-F | PVC control cable, oil resistant, unscreened | PVC control cable with increased oil resistant outer sheath for use as control and connecting cable for fixed laying and flexible applications in electrical devices, without tensile stress and/or guided movements. The cables are intended for indoor applications in dry, damp and wet rooms. | Download |
Control and Electronics Cables | H05VVC4V5-K | PVC control cable, oil resistant, screened | PVC control cable with increased oil resistant outer sheath for use as control and connecting cable for fixed laying and flexible applications in electrical devices, without tensile stress and/or guided movements. The cables are intended for indoor applications in dry, damp and wet rooms, especially when excellent EMC characteristics are requested. | Download |
Control and Electronics Cables | LiYY | Electronic control cable, unscreened | In the electronics of measuring and control devices for the transmission of signals in the range of milliamperes. | Download |
Control and Electronics Cables | L-Y(St)Y EIB | Motor power supply cable for EIB-Bus, halogen-free, screened | For installation on and under plaster in dry, damp and wet locations, as a BUS cable (EIB installation bus) and as a measuring and control cable in power installations. | Download |
Control and Electronics Cables | LiYCY | Electronic control cable, screened | In the electronics of measuring and control devices for the transmission of signals in the range of milliamperes, protected against crosstalks between the circuits and against external electrical influences. | Download |
Control and Electronics Cables | LiYCY-P | Electronic control cable, screened | In the electronics of measuring and control devices for the transmission of signals in the range of milliamperes. Protected against crosstalks between the circuits and against external electrical influences. | Download |
Halogen-free Energy Cables | NHXH FE180/E90 | SI/FRNC energy cable with insulation integrity FE180 and circuit integrity E90 | Suitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. | Download |
Control and Electronics Cables | JE-LiYCY...Bd | Control cable for industrial electronics, screened | In the electronics of measuring and control devices for the transmission of signals in the range of milliamperes, protected against crosstalks between the circuits and against external electrical influences. | Download |
Control and Electronics Cables | JE-Y(St)Y...Bd | Control cable for industrial electronics, screened | For use in the electronics of control and regulating equipment. Preferably for use in interior premises but also for fixed installation on the exterior walls of buildings. Not suitable for power installations purposes and direct burial. | Download |
Control and Electronics Cables | PROFIBUS | Cable for Profibus (EN 50170) | Connecting cable in machine controls, e.g. as a connecting cable between bus segments. | Download |
Halogen-free Energy Cables | N2XCH | XLPE/FRNC energy cable, screened | These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable to protect people and technical building equipment in the event of fire if circuit integrity is not required. Not allowed for installations underground or in water. The cable is not UV-resistant. | Download |
Rubber energy cables | NGFLGÖU | Rubber flat cable | For connecting movable parts of machine tools, conveyor systems and large equipment where the cable is exposed to bending in only one plane. Suitable for installation in dry, damp and wet rooms and outdoors. | Download |
Silicone-, PUR- and Site Cables | SiA | Silicone insulated wire | This wire is well suited for internal wiring in lamps, instruments, control panels and distributors for low mechanical stress particularly at high ambient temperatures. | Download |
Silicone-, PUR- and Site Cables | SiF | Silicone insulated wire | For operation at environment temperatures above 55°C, for internal wiring of lamps, heating equipment and electrical appliances as well as for switching boxes and distributions. | Download |
Silicone-, PUR- and Site Cables | SiHF | Silicone sheathed cable | Used for internal wiring in dry, damp and wet locations and outdoors, for low mechanical stress. Especially suitable for high ambient temperatures. | Download |
Silicone-, PUR- and Site Cables | H05BQ-F (NGMH11YÖ) | PUR sheated cable | For use in dry, damp or wet rooms with medium mechanical stress. The cables are primarily used in industrial enterprises and construction sites under demanding operating conditions, especially with demanding operating conditions, especially abrasive and grinding stresses. | Download |
Silicone-, PUR- and Site Cables | H07BQ-F (NGMH11YÖ) | PUR Insulated wire | For use in dry, damp or wet rooms with medium mechanical stress. The cables are primarily used in industrial enterprises and construction sites under demanding operating conditions, especially with demanding operating conditions, especially abrasive and grinding stresses. | Download |
Silicone-, PUR- and Site Cables | XYMM K35 | PVC building site cable, cold resistant | Suitable as flexible cable subject to moderate mechanical stress in the open air e.g. on non-professional building sites as well as in dry and damp premises. | Download |
Silicone-, PUR- and Site Cables | AT-N07V3V3-F K35 | Flexible cable, cold resistant | As unprotected installable flexible cable under medium mechanical stress for outdoor applications, e.g. on sites, in professional workshops but also in dry or wet rooms and fixed installations. Allowed for direct installations on hoists, machinery etc. In Austria this cable is registered as official equivalent type for H07RN-F. | Download |
Insulated Overhead Lines | E-A2Y | PE insulated overhead line | Used for fixed installation as overhead power lines up to 1000 V inclusive. Not suitable for direct burial. | Download |
Power cables 0,6-1 kV | E-YY-J or -O | PVC/PVC underground cable | Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air, in water – as permitted by the local building regulations – if no risk of any mechanical damage is to be expected. | Download |
Power cables 0,6-1 kV | NYY-J or -O | PVC/PVC underground cable | Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air, in water - as permitted by the local building regulations - if no risk of any mechanical damage is to be expected. | Download |
Power cables 0,6-1 kV | E-Y2Y | PVC/PE underground cable | Power distribution cable in power stations, industrial installations and switchgears, as well as for local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – under severe mechanical stress during installation and operation. | Download |
Power cables 0,6-1 kV | E-YCY | PVC/PVC underground cable, screened | Power distribution ans control cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water - as permitted by the local building regulations - if protection against shock hazard in the event of mechanical damage or electrical screening is required. | Download |
Power cables 0,6-1 kV | NYCY | PVC/PVC underground cable, screened | Power distribution cables in power stations, industrial installations and switch gears, as well as in local mains. For fixed installation under ground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – if protection against shock hazard in the event of mechanical damage or electrical screening is required. | Download |
Power cables 0,6-1 kV | NYCWY | PVC/PVC underground cable, screened | Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water - as permitted by the local building regulations - if protection against shock hazard in the event of mechanical damage or electrical screening is required. The concentric ceander conductor can be used as PE or PEN conductor and needs not be cut when assembling branch joints. | Download |
Power cables 0,6-1 kV | E-AYY-J or -O | PVC/PVC aluminium underground cable | Power distribution cable for power stations, industrial facilities and switching stations as well as for local power networks. For fixed installation indoors, in cable ducts, outdoors and in water, according to the applicable erection standards, if no risk of mechnaical damage is to be expected. | Download |
Power cables 0,6-1 kV | E-AY2Y-J or -O | PVC/PE Aluminum underground cable | Power distribution cable for power stations, industrial facilities and switching stations as well as for local power networks. For fixed installation indoors, in cable ducts, outdoors and in water, according to the applicable erection standards, if high mechanical stress during installation and service occurs. | Download |
Power Cables 10-30kV | N2XSEY 6/10 kV | XLPE/PVC medium voltage underground multicore cable | For fixed installation in ground, in indoors, ground and in cable ducts for industry and distribution networks in accordance with the applicable installation regulations. | Download |
Power Cables 10-30kV | N2XS(F)2Y 6/10 kV | XLPE/HDPE medium voltage underground cable, longitudinally water-proof | For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. | Download |
Power Cables 10-30kV | N2XS(F)2Y 12/20 kV | XLPE/HDPE medium voltage underground cable, longitudinally water-proof | For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. | Download |
Power Cables 10-30kV | N2XS(F)2Y 18/30 kV | XLPE/HDPE medium voltage underground cable, longitudinally water-proof | For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. | Download |
Power Cables 10-30kV | NA2XS2Y 6/10 kV | XLPE/PE medium voltage aluminium underground cable | For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. | Download |
Power Cables 10-30kV | NA2XS2Y 12/20 kV | XLPE/PE medium voltage aluminium underground cable | For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. | Download |
Power Cables 10-30kV | NA2XS2Y 18/30 kV | XLPE/PE medium voltage aluminium underground cable | For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. | Download |
Power Cables 10-30kV | NA2XS(F)2Y 6/10 kV | XLPE/HDPE medium voltage underground cable, longitudinally water-proof | For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. | Download |
Railway Signalling Cables | S-YY | PVC/PVC railway signalling cable, unscreened | Safety and control cable for fixed installation in railway installations. | Download |
Railway Signalling Cables | S-2YY | PE/PVC railway signalling cable, unscreened | Safety and control cable for fixed installation in railway installations. | Download |
Railway Signalling Cables | S-2Y2YBY single core | Railway signalling cable, unscreened, armoured | Safety and control cable for fixed installation in railway installations. The cables must be protected from the constant influence of sunlight. | Download |
Railway Signalling Cables | S-2Y2YBY quad | Railway signalling cable, unscreened, armoured | Safety and control cable for fixed installation in railway installations. The cables must be protected from the constant influence of sunlight. | Download |
Telecommunication Cables | YYSch | PVC telecommunications installation cable | Signalling cable for indoor telephone and intercom systems. Not suitable for outdoor installation; the cable should not be laid in earth or water or used as an energy cable in power installations. | Download |
Telecommunication Cables | YR | PVC telecommunications installation cable | Optimal use for intercommunication buildings, not qualified for high voltage systems, always install in safe materials (pipes/tubes and channels). | Download |
Telecommunication Cables | F-VYAY | PVC/PVC Installation cable for telecommunication, screened | Switching cable for use in telecommunication and related equipment. Suitable for fixed installation on and under plaster, in dry and damp rooms. | Download |
Telecommunication Cables | F-YAY | PVC/PVC Installation cable for telecommunication, screened | Switching cable for use in telecommunication and related equipment. Suitable for fixed installation on and under plaster, in dry and damp rooms. | Download |
Telecommunication Cables | J-Y(St)Y…Lg | Installation cable, screened | Installation cable for use in telecommunications installations and related installations. Preferably for installation in interior premises but also for fixed installation on exterior walls of buildings. However, not suitable for power installations or direct burial. | Download |
Telecommunication Cables | F-2YA2Y | Telecommunication underground cable, screened | Underground cable for telecommunication installations and related installations. Suitable for installation under ground, in water, cable ducts etc. | Download |
Telecommunication Cables | F-2YC2Y | Telecommunication underground cable, screened | Underground cable for use in telecommunications installations and related installations. Suitable for installation under ground, in water, cable ducts etc. | Download |
Telecommunication Cables | F-2YJA2Y | Telecommunication underground cable, screened, longitudinally water-proof | Underground cable for use in telecommunications installations and related installations. Suitable for installation under ground, in water, cable ducts etc. | Download |
Telecommunication Cables | A-2Y(L)2Y...St III Bd | Telecommunication underground cable, screened | Underground cable for telecommunication installations and related installations. Suitable for installation under ground, in water, cable ducts etc. | Download |
Telecommunication Cables | A-2YF(L)2Y.St III Bd | Telecommunication underground cable, screened, longitudinally water-proof | Underground cable for telecommunication installations and related installations. Suitable for installation under ground, in water, cable ducts etc. | Download |
Telecommunication Cables | BM-YY | PVC Fire alarm cable, unscreened | For fixed indoor installations as connection cable for fire alarm systems. | Download |
Telecommunication Cables | JB-Y(St)Y | Fire alarm cable, screened | For the fixed installation for indoors as installation cabble in fire alarm systems. | Download |
Halogen-free Energy Cables | H05Z-K | Insulated wire, halogen-free, fine wire | For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire. | Download |
Halogen-free Energy Cables | H07Z-U | Insulated wire, halogen-free, solid | For fixed installation in conduits on or under plaster. Suitable for the protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire. | Download |
Halogen-free Energy Cables | H07Z-R | Insulated wire, halogen-free, multi core | For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire. | Download |
Halogen-free Energy Cables | HSLH-JZ or -OZ | Control cable, halogen-free, unscreened | As flexible control and connecting cable for fixed laying and flexible applications without tensile stress and/or without guided movements, especially for the protection of human life and valuable equipment. | Download |
Halogen-free Energy Cables | HSLCH-JZ or -OZ | Control cable, halogen-free, screened | As flexible control and connecting cable for fixed laying and flexible applications without tensile stress and/or without guided movements, especially for the protection of human life and valuable equipment. | Download |
Halogen-free Energy Cables | NHXMH | XLPE/FRNC installation cable | Cable for fixed installation on, in and under plaster, in dry, damp and wet locations and in masonry. Not suitable for installation in concrete or outdoors. The halogen-free cable provides improved fire resistance and is primarily used where large concentrations of people and valuable assets must be protected from fire damage. | Download |
Halogen-free Energy Cables | N2XH | XLPE/FRNC energy cable | These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable to protect people and technical building equipment in the event of fire if circuit integrity is not required. Not allowed for installations underground or in water. The cable is not UV-resistant. | Download |
Halogen-free Energy Cables | (N)HXH FE180/E30 (VDE) | SI/FRNC energy cable with insulation integrity FE180 and circuit integrity E30 | Suitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. | Download |
Halogen-free Energy Cables | (N)HXCH FE180/E30 (VDE) | SI/FRNC cable, with insulation integrity FE180 and circuit integrity E30, screened | Suitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. | Download |
Halogen-free Energy Cables | NHXCH FE180/E90 | SI/FRNC energy cable, with insulation integrity FE180 and circuit integrity E90, screened | TSuitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. | Download |
Halogen-free Energy Cables | J-H(St)H...Bd | Control cable, halogen-free, screened | For use in telecommunications and similar systems. Not suitable for power installations, underground laying or outdoor applications. | Download |
Halogen-free Energy Cables | JB-H(St)H...Bd | Fire alarm cable, halogen-free, screened | For use in fire alarm systems. Preferably for indoor applications but also for permanent outdoor installation under protection against solar radiation. Not usable as power cable and/or in earth. | Download |
Halogen-free Energy Cables | JB-H(St)H...Bd FE180/E30 | Fire alarm cable, with insulation integrity FE180 and circuit integrity E30, screened | For use in fire alarm systems where functional integrity is required. Predominantly for indoor applications, but also for fixed installation outdoors if protected from sunlight. Not suitable for power installations and underground laying. | Download |
Halogen-free Energy Cables | JB-H(St)H...Bd FE180/E90 | Fire alarm cable, with insulation integrity FE180 and circuit integrity E90, screened | For use in fire alarm systems where functional integrity is required. Predominantly for indoor applications, but also for fixed installation outdoors if protected from sunlight. Not suitable for power installations and underground laying. | Download |
Halogen-free Energy Cables | JE-H(St)H...Bd FE180/E30 or | Industry electronic control cable, with insulation integrity FE180 and circuit integrity E30, screened | Measuring and control cable providing functional integrity in the event of fire. Not designed for laying in earth or water. Not UV- and water resistant. | Download |
Halogen-free Energy Cables | JE-H(St)H...Bd FE180/E90 or | Industry electronic control cable, with insulation integrity FE180 and circuit integrity E90, screened | Measuring and control cable providing functional integrity in the event of fire. Not designed for laying in earth or water. Not UV and water resistant. | Download |
Halogen-free Energy Cables | L-H(St)H EIB | Motor power supply cable for EIB-Bus, halogen-free, screened | For installation on and under plaster in dry, damp and wet locations, as a BUS cable (EIB installation bus) and as a measuring and control cable in power installations. | Download |
Bare conductors | CU-Seil soft | Cu rope, soft, compressed | Conductors are designed for connection of points with equal electric potential or for high currents. | Download |
Bare conductors | CU-Seil hard acc. 48201 | CU rope hard acc. to 48201 | Conductors are designed for connection of points with equal electric potential or for high currents. | Download |
Get in Touch