Product Search


Product Group Name Type Application Data Sheet
PVC Energy cables H05V-U (YSe) PVC Insulated wire, single core For fixed and protected installation within appliances as well as in and on luminaires. Permissible for installation in conduitson and under plaster but only for control and signal circuits. Download
PVC Energy cables H05V-K (YSf) PVC insulated wire, fine core For fixed and protected installation within appliances as well as in and on luminaires. Permissible for installation in conduits on and under plaster but only for control and signal circuits. Download
PVC Energy cables H07V-U (Ye) PVC Insulated wire, single core For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. Download
PVC Energy cables H07V-R (Ym) PVC Insulated wire, stranded For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. Download
PVC Energy cables H07V-K (Yf) PVC Insulated wire, fine core For fixed installation in conduits on or under plaster. Suitable for protected installation. Download
PVC Energy cables H03VV-F (YML) PVC flexible cable, light-duty Suitable for low mechanical stress in households and offices as well for household appliances. Not suitable for outdoor installation, in commercial establishments or for the connection of commercially used power tools. Download
PVC Energy cables H05VV-F (YMM) PVC Control cable, medium duty Suitable for medium mechanical stress in households and offices as well for household appliances (also in damp rooms). Not suitable for outdoor installation, in commercial establishments or for the connection of commercially used power tools. Download
PVC Energy cables AT-H05VV-U or -R (YM) Installation cable For fixed installation in dry and damp premises. Not suitable for unprotected installation in the open air or directly in tamped concrete. Download
PVC Energy cables NYM-J or -O PVC installation cable For the fixed installation in dry and damp premises. Not suitable for unprotected installation in the open air or directly in tamped concrete. Download
Rubber energy cables H05RR-F (GML) Light rubber flexible cable For use with light to moderate mechanical stressing in households and office premises for light electrical equipment. Not suitable for continuous use in the open air or for use in premises used industrially. Download
Rubber energy cables H01N2-D (NSLFFöu) Rubber welding cable Singel core cable for connection to electrofusion units as handheld electrode cable or as ground cable for use in dry, damp rooms and outdoors. H01N2-E (finest wire) on request. Download
Rubber energy cables H07RN-F (GMSuö) Heavy flexible cable, oil resistant Usable under medium to heavy mechanical stress in dry and wet rooms, in in free ambient or rooms subject to explosion hazards. Permissible for fixed installation on hoisting equipments, machinery etc. and for rated voltages up to 1000 V if installed protected in tubes or inside of devices and as motor power supply cable. Download
Rubber energy cables NSGAFÖU (Ghuöf) Special rubber cable, single core For application in busses and railborn vehicles, in dry rooms, if used in distribution or switching appliances up to 1000 V, it is considered to be short circuit proof. Download
Control and Electronics Cables YSLY-OZ or -OZ PVC Control cable, unscreened For the electrical interconnection of components of production facilities and machine tools. Limited resistant against universal mineral oil and not intended for permanent use submerged in oil. This cable is intended for indoor use and should be installed mechanically protected. Download
Control and Electronics Cables YSLY-JB or -OB PVC Control cable, unscreened For the electrical connection of components of production machines and machine tools. Shows some resistance to all-purpose mineral oil and is not designed for permanent usage in oil baths. The cable is designed for use in buildings and should be installed with mechanical protection. Download
Control and Electronics Cables YSLCY-JZ or -OZ PVC Control cable, screened For the electrical connection of components of production machines and machine tools if a certain level of electronic screening is required. Shows some resistance to all purpose mineral oil and is not designed for permanent useage in oil baths. This cable is designed for use within buildings and should be installed with mechanical protection.. Download
Control and Electronics Cables YSLYCY-JZ or -OZ 600 PVC control cable, oil resistant, screened Flexible power, process control and instrumentation cable for industry and machinery environment with specific EMC (electromagnetic compatibility) requirements. The cable is resistant to UV-irradiation, to most commonly used chemicals and to oil and grease. For indoor and outdoor application. Download
Control and Electronics Cables 2YSL(St)CY-J 0,6/1 kV EMV PE/PVC motor power supply cable, screened Double screened 2YSL(St)CY-J cables were designed as supply and connecting cables, for medium mechanical stress, fixed installation and occasionally non-guided movements, in dry, damp and wet rooms. UV-resistant black sheath is designed for outdoor applications. Double screening considerably improves electromagnetic compatibility (EMC) in buildings and plants. Download
Control and Electronics Cables H05VV5-F PVC control cable, oil resistant, unscreened PVC control cable with increased oil resistant outer sheath for use as control and connecting cable for fixed laying and flexible applications in electrical devices, without tensile stress and/or guided movements. The cables are intended for indoor applications in dry, damp and wet rooms. Download
Control and Electronics Cables H05VVC4V5-K PVC control cable, oil resistant, screened PVC control cable with increased oil resistant outer sheath for use as control and connecting cable for fixed laying and flexible applications in electrical devices, without tensile stress and/or guided movements. The cables are intended for indoor applications in dry, damp and wet rooms, especially when excellent EMC characteristics are requested. Download
Control and Electronics Cables LiYY Electronic control cable, unscreened In the electronics of measuring and control devices for the transmission of signals in the range of milliamperes. Download
Control and Electronics Cables L-Y(St)Y EIB Motor power supply cable for EIB-Bus, halogen-free, screened For installation on and under plaster in dry, damp and wet locations, as a BUS cable (EIB installation bus) and as a measuring and control cable in power installations. Download
Control and Electronics Cables LiYCY Electronic control cable, screened In the electronics of measuring and control devices for the transmission of signals in the range of milliamperes, protected against crosstalks between the circuits and against external electrical influences. Download
Control and Electronics Cables LiYCY-P Electronic control cable, screened In the electronics of measuring and control devices for the transmission of signals in the range of milliamperes. Protected against crosstalks between the circuits and against external electrical influences. Download
Halogen-free Energy Cables NHXH FE180/E90 SI/FRNC energy cable with insulation integrity FE180 and circuit integrity E90 Suitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. Download
Control and Electronics Cables JE-LiYCY...Bd Control cable for industrial electronics, screened In the electronics of measuring and control devices for the transmission of signals in the range of milliamperes, protected against crosstalks between the circuits and against external electrical influences. Download
Control and Electronics Cables JE-Y(St)Y...Bd Control cable for industrial electronics, screened For use in the electronics of control and regulating equipment. Preferably for use in interior premises but also for fixed installation on the exterior walls of buildings. Not suitable for power installations purposes and direct burial. Download
Control and Electronics Cables PROFIBUS Cable for Profibus (EN 50170) Connecting cable in machine controls, e.g. as a connecting cable between bus segments. Download
Halogen-free Energy Cables N2XCH XLPE/FRNC energy cable, screened These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable to protect people and technical building equipment in the event of fire if circuit integrity is not required. Not allowed for installations underground or in water. The cable is not UV-resistant. Download
Rubber energy cables NGFLGÖU Rubber flat cable For connecting movable parts of machine tools, conveyor systems and large equipment where the cable is exposed to bending in only one plane. Suitable for installation in dry, damp and wet rooms and outdoors. Download
Silicone-, PUR- and Site Cables SiA Silicone insulated wire This wire is well suited for internal wiring in lamps, instruments, control panels and distributors for low mechanical stress particularly at high ambient temperatures. Download
Silicone-, PUR- and Site Cables SiF Silicone insulated wire For operation at environment temperatures above 55°C, for internal wiring of lamps, heating equipment and electrical appliances as well as for switching boxes and distributions. Download
Silicone-, PUR- and Site Cables SiHF Silicone sheathed cable Used for internal wiring in dry, damp and wet locations and outdoors, for low mechanical stress. Especially suitable for high ambient temperatures. Download
Silicone-, PUR- and Site Cables H05BQ-F (NGMH11YÖ) PUR sheated cable For use in dry, damp or wet rooms with medium mechanical stress. The cables are primarily used in industrial enterprises and construction sites under demanding operating conditions, especially with demanding operating conditions, especially abrasive and grinding stresses. Download
Silicone-, PUR- and Site Cables H07BQ-F (NGMH11YÖ) PUR Insulated wire For use in dry, damp or wet rooms with medium mechanical stress. The cables are primarily used in industrial enterprises and construction sites under demanding operating conditions, especially with demanding operating conditions, especially abrasive and grinding stresses. Download
Silicone-, PUR- and Site Cables XYMM K35 PVC building site cable, cold resistant Suitable as flexible cable subject to moderate mechanical stress in the open air e.g. on non-professional building sites as well as in dry and damp premises. Download
Silicone-, PUR- and Site Cables AT-N07V3V3-F K35 Flexible cable, cold resistant As unprotected installable flexible cable under medium mechanical stress for outdoor applications, e.g. on sites, in professional workshops but also in dry or wet rooms and fixed installations. Allowed for direct installations on hoists, machinery etc. In Austria this cable is registered as official equivalent type for H07RN-F. Download
Insulated Overhead Lines E-A2Y PE insulated overhead line Used for fixed installation as overhead power lines up to 1000 V inclusive. Not suitable for direct burial. Download
Power cables 0,6-1 kV E-YY-J or -O PVC/PVC underground cable Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air, in water – as permitted by the local building regulations – if no risk of any mechanical damage is to be expected. Download
Power cables 0,6-1 kV NYY-J or -O PVC/PVC underground cable Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air, in water - as permitted by the local building regulations - if no risk of any mechanical damage is to be expected. Download
Power cables 0,6-1 kV E-Y2Y PVC/PE underground cable Power distribution cable in power stations, industrial installations and switchgears, as well as for local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – under severe mechanical stress during installation and operation. Download
Power cables 0,6-1 kV E-YCY PVC/PVC underground cable, screened Power distribution ans control cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water - as permitted by the local building regulations - if protection against shock hazard in the event of mechanical damage or electrical screening is required. Download
Power cables 0,6-1 kV NYCY PVC/PVC underground cable, screened Power distribution cables in power stations, industrial installations and switch gears, as well as in local mains. For fixed installation under ground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – if protection against shock hazard in the event of mechanical damage or electrical screening is required. Download
Power cables 0,6-1 kV NYCWY PVC/PVC underground cable, screened Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water - as permitted by the local building regulations - if protection against shock hazard in the event of mechanical damage or electrical screening is required. The concentric ceander conductor can be used as PE or PEN conductor and needs not be cut when assembling branch joints. Download
Power cables 0,6-1 kV E-AYY-J or -O PVC/PVC aluminium underground cable Power distribution cable for power stations, industrial facilities and switching stations as well as for local power networks. For fixed installation indoors, in cable ducts, outdoors and in water, according to the applicable erection standards, if no risk of mechnaical damage is to be expected. Download
Power cables 0,6-1 kV E-AY2Y-J or -O PVC/PE Aluminum underground cable Power distribution cable for power stations, industrial facilities and switching stations as well as for local power networks. For fixed installation indoors, in cable ducts, outdoors and in water, according to the applicable erection standards, if high mechanical stress during installation and service occurs. Download
Power Cables 10-30kV N2XSEY 6/10 kV XLPE/PVC medium voltage underground multicore cable For fixed installation in ground, in indoors, ground and in cable ducts for industry and distribution networks in accordance with the applicable installation regulations. Download
Power Cables 10-30kV N2XS(F)2Y 6/10 kV XLPE/HDPE medium voltage underground cable, longitudinally water-proof For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Download
Power Cables 10-30kV N2XS(F)2Y 12/20 kV XLPE/HDPE medium voltage underground cable, longitudinally water-proof For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Download
Power Cables 10-30kV N2XS(F)2Y 18/30 kV XLPE/HDPE medium voltage underground cable, longitudinally water-proof For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Download
Power Cables 10-30kV NA2XS2Y 6/10 kV XLPE/PE medium voltage aluminium underground cable For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Download
Power Cables 10-30kV NA2XS2Y 12/20 kV XLPE/PE medium voltage aluminium underground cable For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Download
Power Cables 10-30kV NA2XS2Y 18/30 kV XLPE/PE medium voltage aluminium underground cable For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Download
Power Cables 10-30kV NA2XS(F)2Y 6/10 kV XLPE/HDPE medium voltage underground cable, longitudinally water-proof For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Download
Railway Signalling Cables S-YY PVC/PVC railway signalling cable, unscreened Safety and control cable for fixed installation in railway installations. Download
Railway Signalling Cables S-2YY PE/PVC railway signalling cable, unscreened Safety and control cable for fixed installation in railway installations. Download
Railway Signalling Cables S-2Y2YBY single core Railway signalling cable, unscreened, armoured Safety and control cable for fixed installation in railway installations. The cables must be protected from the constant influence of sunlight. Download
Railway Signalling Cables S-2Y2YBY quad Railway signalling cable, unscreened, armoured Safety and control cable for fixed installation in railway installations. The cables must be protected from the constant influence of sunlight. Download
Telecommunication Cables YYSch PVC telecommunications installation cable Signalling cable for indoor telephone and intercom systems. Not suitable for outdoor installation; the cable should not be laid in earth or water or used as an energy cable in power installations. Download
Telecommunication Cables YR PVC telecommunications installation cable Optimal use for intercommunication buildings, not qualified for high voltage systems, always install in safe materials (pipes/tubes and channels). Download
Telecommunication Cables F-VYAY PVC/PVC Installation cable for telecommunication, screened Switching cable for use in telecommunication and related equipment. Suitable for fixed installation on and under plaster, in dry and damp rooms. Download
Telecommunication Cables F-YAY PVC/PVC Installation cable for telecommunication, screened Switching cable for use in telecommunication and related equipment. Suitable for fixed installation on and under plaster, in dry and damp rooms. Download
Telecommunication Cables J-Y(St)Y…Lg Installation cable, screened Installation cable for use in telecommunications installations and related installations. Preferably for installation in interior premises but also for fixed installation on exterior walls of buildings. However, not suitable for power installations or direct burial. Download
Telecommunication Cables F-2YA2Y Telecommunication underground cable, screened Underground cable for telecommunication installations and related installations. Suitable for installation under ground, in water, cable ducts etc. Download
Telecommunication Cables F-2YC2Y Telecommunication underground cable, screened Underground cable for use in telecommunications installations and related installations. Suitable for installation under ground, in water, cable ducts etc. Download
Telecommunication Cables F-2YJA2Y Telecommunication underground cable, screened, longitudinally water-proof Underground cable for use in telecommunications installations and related installations. Suitable for installation under ground, in water, cable ducts etc. Download
Telecommunication Cables A-2Y(L)2Y...St III Bd Telecommunication underground cable, screened Underground cable for telecommunication installations and related installations. Suitable for installation under ground, in water, cable ducts etc. Download
Telecommunication Cables A-2YF(L)2Y.St III Bd Telecommunication underground cable, screened, longitudinally water-proof Underground cable for telecommunication installations and related installations. Suitable for installation under ground, in water, cable ducts etc. Download
Telecommunication Cables BM-YY PVC Fire alarm cable, unscreened For fixed indoor installations as connection cable for fire alarm systems. Download
Telecommunication Cables JB-Y(St)Y Fire alarm cable, screened For the fixed installation for indoors as installation cabble in fire alarm systems. Download
Halogen-free Energy Cables H05Z-K Insulated wire, halogen-free, fine wire For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire. Download
Halogen-free Energy Cables H07Z-U Insulated wire, halogen-free, solid For fixed installation in conduits on or under plaster. Suitable for the protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire. Download
Halogen-free Energy Cables H07Z-R Insulated wire, halogen-free, multi core For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire. Download
Halogen-free Energy Cables HSLH-JZ or -OZ Control cable, halogen-free, unscreened As flexible control and connecting cable for fixed laying and flexible applications without tensile stress and/or without guided movements, especially for the protection of human life and valuable equipment. Download
Halogen-free Energy Cables HSLCH-JZ or -OZ Control cable, halogen-free, screened As flexible control and connecting cable for fixed laying and flexible applications without tensile stress and/or without guided movements, especially for the protection of human life and valuable equipment. Download
Halogen-free Energy Cables NHXMH XLPE/FRNC installation cable Cable for fixed installation on, in and under plaster, in dry, damp and wet locations and in masonry. Not suitable for installation in concrete or outdoors. The halogen-free cable provides improved fire resistance and is primarily used where large concentrations of people and valuable assets must be protected from fire damage. Download
Halogen-free Energy Cables N2XH XLPE/FRNC energy cable These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable to protect people and technical building equipment in the event of fire if circuit integrity is not required. Not allowed for installations underground or in water. The cable is not UV-resistant. Download
Halogen-free Energy Cables (N)HXH FE180/E30 (VDE) SI/FRNC energy cable with insulation integrity FE180 and circuit integrity E30 Suitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. Download
Halogen-free Energy Cables (N)HXCH FE180/E30 (VDE) SI/FRNC cable, with insulation integrity FE180 and circuit integrity E30, screened Suitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. Download
Halogen-free Energy Cables NHXCH FE180/E90 SI/FRNC energy cable, with insulation integrity FE180 and circuit integrity E90, screened TSuitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. Download
Halogen-free Energy Cables J-H(St)H...Bd Control cable, halogen-free, screened For use in telecommunications and similar systems. Not suitable for power installations, underground laying or outdoor applications. Download
Halogen-free Energy Cables JB-H(St)H...Bd Fire alarm cable, halogen-free, screened For use in fire alarm systems. Preferably for indoor applications but also for permanent outdoor installation under protection against solar radiation. Not usable as power cable and/or in earth. Download
Halogen-free Energy Cables JB-H(St)H...Bd FE180/E30 Fire alarm cable, with insulation integrity FE180 and circuit integrity E30, screened For use in fire alarm systems where functional integrity is required. Predominantly for indoor applications, but also for fixed installation outdoors if protected from sunlight. Not suitable for power installations and underground laying. Download
Halogen-free Energy Cables JB-H(St)H...Bd FE180/E90 Fire alarm cable, with insulation integrity FE180 and circuit integrity E90, screened For use in fire alarm systems where functional integrity is required. Predominantly for indoor applications, but also for fixed installation outdoors if protected from sunlight. Not suitable for power installations and underground laying. Download
Halogen-free Energy Cables JE-H(St)H...Bd FE180/E30 or Industry electronic control cable, with insulation integrity FE180 and circuit integrity E30, screened Measuring and control cable providing functional integrity in the event of fire. Not designed for laying in earth or water. Not UV- and water resistant. Download
Halogen-free Energy Cables JE-H(St)H...Bd FE180/E90 or Industry electronic control cable, with insulation integrity FE180 and circuit integrity E90, screened Measuring and control cable providing functional integrity in the event of fire. Not designed for laying in earth or water. Not UV and water resistant. Download
Halogen-free Energy Cables L-H(St)H EIB Motor power supply cable for EIB-Bus, halogen-free, screened For installation on and under plaster in dry, damp and wet locations, as a BUS cable (EIB installation bus) and as a measuring and control cable in power installations. Download
Bare conductors CU-Seil soft Cu rope, soft, compressed Conductors are designed for connection of points with equal electric potential or for high currents. Download
Bare conductors CU-Seil hard acc. 48201 CU rope hard acc. to 48201 Conductors are designed for connection of points with equal electric potential or for high currents. Download

Get in Touch