Name | Type | Application | Data Sheet |
---|---|---|---|
E-YY-J or -O | PVC/PVC underground cable | Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air, in water – as permitted by the local building regulations – if no risk of any mechanical damage is to be expected. | Download |
NYY-J or -O | PVC/PVC underground cable | Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air, in water - as permitted by the local building regulations - if no risk of any mechanical damage is to be expected. | Download |
E-Y2Y | PVC/PE underground cable | Power distribution cable in power stations, industrial installations and switchgears, as well as for local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – under severe mechanical stress during installation and operation. | Download |
E-YCY | PVC/PVC underground cable, screened | Power distribution ans control cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water - as permitted by the local building regulations - if protection against shock hazard in the event of mechanical damage or electrical screening is required. | Download |
NYCY | PVC/PVC underground cable, screened | Power distribution cables in power stations, industrial installations and switch gears, as well as in local mains. For fixed installation under ground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – if protection against shock hazard in the event of mechanical damage or electrical screening is required. | Download |
NYCWY | PVC/PVC underground cable, screened | Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water - as permitted by the local building regulations - if protection against shock hazard in the event of mechanical damage or electrical screening is required. The concentric ceander conductor can be used as PE or PEN conductor and needs not be cut when assembling branch joints. | Download |
E-AYY-J or -O | PVC/PVC aluminium underground cable | Power distribution cable for power stations, industrial facilities and switching stations as well as for local power networks. For fixed installation indoors, in cable ducts, outdoors and in water, according to the applicable erection standards, if no risk of mechnaical damage is to be expected. | Download |
E-AY2Y-J or -O | PVC/PE Aluminum underground cable | Power distribution cable for power stations, industrial facilities and switching stations as well as for local power networks. For fixed installation indoors, in cable ducts, outdoors and in water, according to the applicable erection standards, if high mechanical stress during installation and service occurs. | Download |