Halogen-free Energy Cables

Name | Type | Application | Data Sheet |
---|---|---|---|
NHXH FE180/E90 | SI/FRNC energy cable with insulation integrity FE180 and circuit integrity E90 | Suitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. | Download |
N2XCH | XLPE/FRNC energy cable, screened | These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable to protect people and technical building equipment in the event of fire if circuit integrity is not required. Not allowed for installations underground or in water. The cable is not UV-resistant. | Download |
H05Z-K | Insulated wire, halogen-free, fine wire | For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire. | Download |
H07Z-U | Insulated wire, halogen-free, solid | For fixed installation in conduits on or under plaster. Suitable for the protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire. | Download |
H07Z-R | Insulated wire, halogen-free, multi core | For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire. | Download |
HSLH-JZ or -OZ | Control cable, halogen-free, unscreened | As flexible control and connecting cable for fixed laying and flexible applications without tensile stress and/or without guided movements, especially for the protection of human life and valuable equipment. | Download |
HSLCH-JZ or -OZ | Control cable, halogen-free, screened | As flexible control and connecting cable for fixed laying and flexible applications without tensile stress and/or without guided movements, especially for the protection of human life and valuable equipment. | Download |
NHXMH | XLPE/FRNC installation cable | Cable for fixed installation on, in and under plaster, in dry, damp and wet locations and in masonry. Not suitable for installation in concrete or outdoors. The halogen-free cable provides improved fire resistance and is primarily used where large concentrations of people and valuable assets must be protected from fire damage. | Download |
N2XH | XLPE/FRNC energy cable | These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable to protect people and technical building equipment in the event of fire if circuit integrity is not required. Not allowed for installations underground or in water. The cable is not UV-resistant. | Download |
(N)HXH FE180/E30 (VDE) | SI/FRNC energy cable with insulation integrity FE180 and circuit integrity E30 | Suitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. | Download |
(N)HXCH FE180/E30 (VDE) | SI/FRNC cable, with insulation integrity FE180 and circuit integrity E30, screened | Suitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. | Download |
NHXCH FE180/E90 | SI/FRNC energy cable, with insulation integrity FE180 and circuit integrity E90, screened | TSuitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. | Download |
J-H(St)H...Bd | Control cable, halogen-free, screened | For use in telecommunications and similar systems. Not suitable for power installations, underground laying or outdoor applications. | Download |
JB-H(St)H...Bd | Fire alarm cable, halogen-free, screened | For use in fire alarm systems. Preferably for indoor applications but also for permanent outdoor installation under protection against solar radiation. Not usable as power cable and/or in earth. | Download |
JB-H(St)H...Bd FE180/E30 | Fire alarm cable, with insulation integrity FE180 and circuit integrity E30, screened | For use in fire alarm systems where functional integrity is required. Predominantly for indoor applications, but also for fixed installation outdoors if protected from sunlight. Not suitable for power installations and underground laying. | Download |
JB-H(St)H...Bd FE180/E90 | Fire alarm cable, with insulation integrity FE180 and circuit integrity E90, screened | For use in fire alarm systems where functional integrity is required. Predominantly for indoor applications, but also for fixed installation outdoors if protected from sunlight. Not suitable for power installations and underground laying. | Download |
JE-H(St)H...Bd FE180/E30 or | Industry electronic control cable, with insulation integrity FE180 and circuit integrity E30, screened | Measuring and control cable providing functional integrity in the event of fire. Not designed for laying in earth or water. Not UV- and water resistant. | Download |
JE-H(St)H...Bd FE180/E90 or | Industry electronic control cable, with insulation integrity FE180 and circuit integrity E90, screened | Measuring and control cable providing functional integrity in the event of fire. Not designed for laying in earth or water. Not UV and water resistant. | Download |
L-H(St)H EIB | Motor power supply cable for EIB-Bus, halogen-free, screened | For installation on and under plaster in dry, damp and wet locations, as a BUS cable (EIB installation bus) and as a measuring and control cable in power installations. | Download |