Hledání produktu


SKUPINY PRODUKTŮ Označení Typ Žádost Datový list
SILOVÁ VEDENÍ Z PVC H05V-U (YSe) PVC Insulated wire, single core For fixed and protected installation within appliances as well as in and on luminaires. Permissible for installation in conduitson and under plaster but only for control and signal circuits. Stahování
SILOVÁ VEDENÍ Z PVC H05V-K (YSf) PVC insulated wire, fine core For fixed and protected installation within appliances as well as in and on luminaires. Permissible for installation in conduits on and under plaster but only for control and signal circuits. Stahování
SILOVÁ VEDENÍ Z PVC H07V-U (Ye) PVC Insulated wire, single core For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. Stahování
SILOVÁ VEDENÍ Z PVC H07V-R (Ym) PVC Insulated wire, stranded For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. Stahování
SILOVÁ VEDENÍ Z PVC H07V-K (Yf) PVC Insulated wire, fine core For fixed installation in conduits on or under plaster. Suitable for protected installation. Stahování
SILOVÁ VEDENÍ Z PVC H03VV-F (YML) PVC flexible cable, light-duty Suitable for low mechanical stress in households and offices as well for household appliances. Not suitable for outdoor installation, in commercial establishments or for the connection of commercially used power tools. Stahování
SILOVÁ VEDENÍ Z PVC H05VV-F (YMM) PVC Control cable, medium duty Suitable for medium mechanical stress in households and offices as well for household appliances (also in damp rooms). Not suitable for outdoor installation, in commercial establishments or for the connection of commercially used power tools. Stahování
SILOVÁ VEDENÍ Z PVC AT-H05VV-U or -R (YM) Installation cable For fixed installation in dry and damp premises. Not suitable for unprotected installation in the open air or directly in tamped concrete. Stahování
SILOVÁ VEDENÍ Z PVC NYM-J or -O PVC installation cable For the fixed installation in dry and damp premises. Not suitable for unprotected installation in the open air or directly in tamped concrete. Stahování
SILOVÁ VEDENÍ Z PRYŽE H05RR-F (GML) Light rubber flexible cable For use with light to moderate mechanical stressing in households and office premises for light electrical equipment. Not suitable for continuous use in the open air or for use in premises used industrially. Stahování
SILOVÁ VEDENÍ Z PRYŽE H01N2-D (NSLFFöu) Rubber welding cable Singel core cable for connection to electrofusion units as handheld electrode cable or as ground cable for use in dry, damp rooms and outdoors. H01N2-E (finest wire) on request. Stahování
SILOVÁ VEDENÍ Z PRYŽE H07RN-F (GMSuö) Heavy flexible cable, oil resistant Usable under medium to heavy mechanical stress in dry and wet rooms, in in free ambient or rooms subject to explosion hazards. Permissible for fixed installation on hoisting equipments, machinery etc. and for rated voltages up to 1000 V if installed protected in tubes or inside of devices and as motor power supply cable. Stahování
SILOVÁ VEDENÍ Z PRYŽE NSGAFÖU (Ghuöf) Special rubber cable, single core For application in busses and railborn vehicles, in dry rooms, if used in distribution or switching appliances up to 1000 V, it is considered to be short circuit proof. Stahování
Vedení pro ovládání a elektroniku YSLY-OZ or -OZ PVC Control cable, unscreened For the electrical interconnection of components of production facilities and machine tools. Limited resistant against universal mineral oil and not intended for permanent use submerged in oil. This cable is intended for indoor use and should be installed mechanically protected. Stahování
Vedení pro ovládání a elektroniku YSLY-JB or -OB PVC Control cable, unscreened For the electrical connection of components of production machines and machine tools. Shows some resistance to all-purpose mineral oil and is not designed for permanent usage in oil baths. The cable is designed for use in buildings and should be installed with mechanical protection. Stahování
Vedení pro ovládání a elektroniku YSLCY-JZ or -OZ PVC Control cable, screened For the electrical connection of components of production machines and machine tools if a certain level of electronic screening is required. Shows some resistance to all purpose mineral oil and is not designed for permanent useage in oil baths. This cable is designed for use within buildings and should be installed with mechanical protection.. Stahování
Vedení pro ovládání a elektroniku YSLYCY-JZ or -OZ 600 PVC control cable, oil resistant, screened Flexible power, process control and instrumentation cable for industry and machinery environment with specific EMC (electromagnetic compatibility) requirements. The cable is resistant to UV-irradiation, to most commonly used chemicals and to oil and grease. For indoor and outdoor application. Stahování
Vedení pro ovládání a elektroniku 2YSL(St)CY-J 0,6/1 kV EMV PE/PVC motor power supply cable, screened Double screened 2YSL(St)CY-J cables were designed as supply and connecting cables, for medium mechanical stress, fixed installation and occasionally non-guided movements, in dry, damp and wet rooms. UV-resistant black sheath is designed for outdoor applications. Double screening considerably improves electromagnetic compatibility (EMC) in buildings and plants. Stahování
Vedení pro ovládání a elektroniku H05VV5-F PVC control cable, oil resistant, unscreened PVC control cable with increased oil resistant outer sheath for use as control and connecting cable for fixed laying and flexible applications in electrical devices, without tensile stress and/or guided movements. The cables are intended for indoor applications in dry, damp and wet rooms. Stahování
Vedení pro ovládání a elektroniku H05VVC4V5-K PVC control cable, oil resistant, screened PVC control cable with increased oil resistant outer sheath for use as control and connecting cable for fixed laying and flexible applications in electrical devices, without tensile stress and/or guided movements. The cables are intended for indoor applications in dry, damp and wet rooms, especially when excellent EMC characteristics are requested. Stahování
Vedení pro ovládání a elektroniku LiYY Electronic control cable, unscreened In the electronics of measuring and control devices for the transmission of signals in the range of milliamperes. Stahování
Vedení pro ovládání a elektroniku L-Y(St)Y EIB Motor power supply cable for EIB-Bus, halogen-free, screened For installation on and under plaster in dry, damp and wet locations, as a BUS cable (EIB installation bus) and as a measuring and control cable in power installations. Stahování
Vedení pro ovládání a elektroniku LiYCY Electronic control cable, screened In the electronics of measuring and control devices for the transmission of signals in the range of milliamperes, protected against crosstalks between the circuits and against external electrical influences. Stahování
Vedení pro ovládání a elektroniku LiYCY-P Electronic control cable, screened In the electronics of measuring and control devices for the transmission of signals in the range of milliamperes. Protected against crosstalks between the circuits and against external electrical influences. Stahování
Bezhalogenové kabely a vedení NHXH FE180/E90 SI/FRNC energy cable with insulation integrity FE180 and circuit integrity E90 Suitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. Stahování
Vedení pro ovládání a elektroniku JE-LiYCY...Bd Control cable for industrial electronics, screened In the electronics of measuring and control devices for the transmission of signals in the range of milliamperes, protected against crosstalks between the circuits and against external electrical influences. Stahování
Vedení pro ovládání a elektroniku JE-Y(St)Y...Bd Control cable for industrial electronics, screened For use in the electronics of control and regulating equipment. Preferably for use in interior premises but also for fixed installation on the exterior walls of buildings. Not suitable for power installations purposes and direct burial. Stahování
Vedení pro ovládání a elektroniku PROFIBUS Cable for Profibus (EN 50170) Connecting cable in machine controls, e.g. as a connecting cable between bus segments. Stahování
Bezhalogenové kabely a vedení N2XCH XLPE/FRNC energy cable, screened These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable to protect people and technical building equipment in the event of fire if circuit integrity is not required. Not allowed for installations underground or in water. The cable is not UV-resistant. Stahování
SILOVÁ VEDENÍ Z PRYŽE NGFLGÖU Rubber flat cable For connecting movable parts of machine tools, conveyor systems and large equipment where the cable is exposed to bending in only one plane. Suitable for installation in dry, damp and wet rooms and outdoors. Stahování
Silikonová vedení, vedení z PUR a vedení pro staveniště SiA Silicone insulated wire This wire is well suited for internal wiring in lamps, instruments, control panels and distributors for low mechanical stress particularly at high ambient temperatures. Stahování
Silikonová vedení, vedení z PUR a vedení pro staveniště SiF Silicone insulated wire For operation at environment temperatures above 55°C, for internal wiring of lamps, heating equipment and electrical appliances as well as for switching boxes and distributions. Stahování
Silikonová vedení, vedení z PUR a vedení pro staveniště SiHF Silicone sheathed cable Used for internal wiring in dry, damp and wet locations and outdoors, for low mechanical stress. Especially suitable for high ambient temperatures. Stahování
Silikonová vedení, vedení z PUR a vedení pro staveniště H05BQ-F (NGMH11YÖ) PUR sheated cable For use in dry, damp or wet rooms with medium mechanical stress. The cables are primarily used in industrial enterprises and construction sites under demanding operating conditions, especially with demanding operating conditions, especially abrasive and grinding stresses. Stahování
Silikonová vedení, vedení z PUR a vedení pro staveniště H07BQ-F (NGMH11YÖ) PUR Insulated wire For use in dry, damp or wet rooms with medium mechanical stress. The cables are primarily used in industrial enterprises and construction sites under demanding operating conditions, especially with demanding operating conditions, especially abrasive and grinding stresses. Stahování
Silikonová vedení, vedení z PUR a vedení pro staveniště XYMM K35 PVC building site cable, cold resistant Suitable as flexible cable subject to moderate mechanical stress in the open air e.g. on non-professional building sites as well as in dry and damp premises. Stahování
Silikonová vedení, vedení z PUR a vedení pro staveniště AT-N07V3V3-F K35 Flexible cable, cold resistant As unprotected installable flexible cable under medium mechanical stress for outdoor applications, e.g. on sites, in professional workshops but also in dry or wet rooms and fixed installations. Allowed for direct installations on hoists, machinery etc. In Austria this cable is registered as official equivalent type for H07RN-F. Stahování
Izolovaná vrchní vedení E-A2Y PE insulated overhead line Used for fixed installation as overhead power lines up to 1000 V inclusive. Not suitable for direct burial. Stahování
Silové kabely 0,6–1 kV E-YY-J or -O PVC/PVC underground cable Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – if no risk of any mechanical damage is to be expected. Stahování
Silové kabely 0,6–1 kV NYY-J or -O PVC/PVC underground cable Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air, in water - as permitted by the local building regulations - if no risk of any mechanical damage is to be expected. Stahování
Silové kabely 0,6–1 kV E-Y2Y PVC/PE underground cable Power distribution cable in power stations, industrial installations and switchgears, as well as for local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – under severe mechanical stress during installation and operation. Stahování
Silové kabely 0,6–1 kV E-YCY PVC/PVC underground cable, screened Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – if protection against shock hazard in the event of mechanical damage or electrical screening is required. Stahování
Silové kabely 0,6–1 kV NYCY PVC/PVC underground cable, screened Power distribution cables in power stations, industrial installations and switch gears, as well as in local mains. For fixed installation under ground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – if protection against shock hazard in the event of mechanical damage or electrical screening is required. Stahování
Silové kabely 0,6–1 kV NYCWY PVC/PVC underground cable, screened Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water - as permitted by the local building regulations - if protection against shock hazard in the event of mechanical damage or electrical screening is required. The concentric ceander conductor can be used as PE or PEN conductor and needs not be cut when assembling branch joints. Stahování
Silové kabely 0,6–1 kV E-AYY-J or -O PVC/PVC aluminium underground cable Power distribution cable for power stations, industrial facilities and switching stations as well as for local power networks. For fixed installation indoors, in cable ducts, outdoors and in water, according to the applicable erection standards, if no risk of mechnaical damage is to be expected. Stahování
Silové kabely 0,6–1 kV E-AY2Y-J or -O PVC/PE Aluminum underground cable Power distribution cable for power stations, industrial facilities and switching stations as well as for local power networks. For fixed installation indoors, in cable ducts, outdoors and in water, according to the applicable erection standards, if high mechanical stress during installation and service occurs. Stahování
Silové kabely 10–30 kV N2XSEY 6/10 kV XLPE/PVC medium voltage underground multicore cable For fixed installation in ground, in indoors, ground and in cable ducts for industry and distribution networks in accordance with the applicable installation regulations. Stahování
Silové kabely 10–30 kV N2XS(F)2Y 6/10 kV XLPE/HDPE medium voltage underground cable, longitudinally water-proof For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Stahování
Silové kabely 10–30 kV N2XS(F)2Y 12/20 kV XLPE/HDPE medium voltage underground cable, longitudinally water-proof For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Stahování
Silové kabely 10–30 kV N2XS(F)2Y 18/30 kV XLPE/HDPE medium voltage underground cable, longitudinally water-proof For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Stahování
Silové kabely 10–30 kV NA2XS2Y 6/10 kV XLPE/PE medium voltage aluminium underground cable For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Stahování
Silové kabely 10–30 kV NA2XS2Y 12/20 kV XLPE/PE medium voltage aluminium underground cable For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Stahování
Silové kabely 10–30 kV NA2XS2Y 18/30 kV XLPE/PE medium voltage aluminium underground cable For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Stahování
Silové kabely 10–30 kV NA2XS(F)2Y 6/10 kV XLPE/HDPE medium voltage underground cable, longitudinally water-proof For fixed installation for high requirements in the ground subject to external effects of moisture, in the open air and in cable ducts for industrial and distribution mains – as permitted by the local building regulations – under severe mechanical stressing during installation and operation. Stahování
ŽELEZNIČNÍ A ZABEZPEČOVACÍ KABELY S-YY PVC/PVC railway signalling cable, unscreened Safety and control cable for fixed installation in railway installations. Stahování
ŽELEZNIČNÍ A ZABEZPEČOVACÍ KABELY S-2YY PE/PVC railway signalling cable, unscreened Safety and control cable for fixed installation in railway installations. Stahování
ŽELEZNIČNÍ A ZABEZPEČOVACÍ KABELY S-2Y2YBY single core Railway signalling cable, unscreened, armoured Safety and control cable for fixed installation in railway installations. The cables must be protected from the constant influence of sunlight. Stahování
ŽELEZNIČNÍ A ZABEZPEČOVACÍ KABELY S-2Y2YBY quad Railway signalling cable, unscreened, armoured Safety and control cable for fixed installation in railway installations. The cables must be protected from the constant influence of sunlight. Stahování
Sdělovací kabely a vedení YYSch PVC telecommunications installation cable Signalling cable for indoor telephone and intercom systems. Not suitable for outdoor installation; the cable should not be laid in earth or water or used as an energy cable in power installations. Stahování
Sdělovací kabely a vedení YR PVC telecommunications installation cable Optimal use for intercommunication buildings, not qualified for high voltage systems, always install in safe materials (pipes/tubes and channels). Stahování
Sdělovací kabely a vedení F-VYAY PVC/PVC Installation cable for telecommunication, screened Switching cable for use in telecommunication and related equipment. Suitable for fixed installation on and under plaster, in dry and damp rooms. Stahování
Sdělovací kabely a vedení F-YAY PVC/PVC Installation cable for telecommunication, screened Switching cable for use in telecommunication and related equipment. Suitable for fixed installation on and under plaster, in dry and damp rooms. Stahování
Sdělovací kabely a vedení J-Y(St)Y…Lg Installation cable, screened Installation cable for use in telecommunications installations and related installations. Preferably for installation in interior premises but also for fixed installation on exterior walls of buildings. However, not suitable for power installations or direct burial. Stahování
Sdělovací kabely a vedení F-2YA2Y Telecommunication underground cable, screened Underground cable for telecommunication installations and related installations. Suitable for installation under ground, in water, cable ducts etc. Stahování
Sdělovací kabely a vedení F-2YC2Y Telecommunication underground cable, screened Underground cable for use in telecommunications installations and related installations. Suitable for installation under ground, in water, cable ducts etc. Stahování
Sdělovací kabely a vedení F-2YJA2Y Telecommunication underground cable, screened, longitudinally water-proof Underground cable for use in telecommunications installations and related installations. Suitable for installation under ground, in water, cable ducts etc. Stahování
Sdělovací kabely a vedení A-2Y(L)2Y...St III Bd Telecommunication underground cable, screened Underground cable for telecommunication installations and related installations. Suitable for installation under ground, in water, cable ducts etc. Stahování
Sdělovací kabely a vedení A-2YF(L)2Y.St III Bd Telecommunication underground cable, screened, longitudinally water-proof Underground cable for telecommunication installations and related installations. Suitable for installation under ground, in water, cable ducts etc. Stahování
Sdělovací kabely a vedení BM-YY PVC Fire alarm cable, unscreened For fixed indoor installations as connection cable for fire alarm systems. Stahování
Sdělovací kabely a vedení JB-Y(St)Y Fire alarm cable, screened For the fixed installation for indoors as installation cabble in fire alarm systems. Stahování
Bezhalogenové kabely a vedení H05Z-K Insulated wire, halogen-free, fine wire For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire. Stahování
Bezhalogenové kabely a vedení H07Z-U Insulated wire, halogen-free, solid For fixed installation in conduits on or under plaster. Suitable for the protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire. Stahování
Bezhalogenové kabely a vedení H07Z-R Insulated wire, halogen-free, multi core For fixed installation in conduits on or under plaster. Suitable for protected installation in and on lighting facilities or control devices for voltages up to 750 V AC or 1000 V DC against ground. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire. Stahování
Bezhalogenové kabely a vedení HSLH-JZ or -OZ Control cable, halogen-free, unscreened As flexible control and connecting cable for fixed laying and flexible applications without tensile stress and/or without guided movements, especially for the protection of human life and valuable equipment. Stahování
Bezhalogenové kabely a vedení HSLCH-JZ or -OZ Control cable, halogen-free, screened As flexible control and connecting cable for fixed laying and flexible applications without tensile stress and/or without guided movements, especially for the protection of human life and valuable equipment. Stahování
Bezhalogenové kabely a vedení NHXMH XLPE/FRNC installation cable Cable for fixed installation on, in and under plaster, in dry, damp and wet locations and in masonry. Not suitable for installation in concrete or outdoors. The halogen-free cable provides improved fire resistance and is primarily used where large concentrations of people and valuable assets must be protected from fire damage. Stahování
Bezhalogenové kabely a vedení N2XH XLPE/FRNC energy cable These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable to protect people and technical building equipment in the event of fire if circuit integrity is not required. Not allowed for installations underground or in water. The cable is not UV-resistant. Stahování
Bezhalogenové kabely a vedení (N)HXH FE180/E30 (VDE) SI/FRNC energy cable with insulation integrity FE180 and circuit integrity E30 Suitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. Stahování
Bezhalogenové kabely a vedení (N)HXCH FE180/E30 (VDE) SI/FRNC cable, with insulation integrity FE180 and circuit integrity E30, screened Suitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. Stahování
Bezhalogenové kabely a vedení NHXCH FE180/E90 SI/FRNC energy cable, with insulation integrity FE180 and circuit integrity E90, screened TSuitable to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable is not UV-resistant. Stahování
Bezhalogenové kabely a vedení J-H(St)H...Bd Control cable, halogen-free, screened For use in telecommunications and similar systems. Not suitable for power installations, underground laying or outdoor applications. Stahování
Bezhalogenové kabely a vedení JB-H(St)H...Bd Fire alarm cable, halogen-free, screened For use in fire alarm systems. Preferably for indoor applications but also for permanent outdoor installation under protection against solar radiation. Not usable as power cable and/or in earth. Stahování
Bezhalogenové kabely a vedení JB-H(St)H...Bd FE180/E30 Fire alarm cable, with insulation integrity FE180 and circuit integrity E30, screened For use in fire alarm systems where functional integrity is required. Predominantly for indoor applications, but also for fixed installation outdoors if protected from sunlight. Not suitable for power installations and underground laying. Stahování
Bezhalogenové kabely a vedení JB-H(St)H...Bd FE180/E90 Fire alarm cable, with insulation integrity FE180 and circuit integrity E90, screened For use in fire alarm systems where functional integrity is required. Predominantly for indoor applications, but also for fixed installation outdoors if protected from sunlight. Not suitable for power installations and underground laying. Stahování
Bezhalogenové kabely a vedení JE-H(St)H...Bd FE180/E30 or Industry electronic control cable, with insulation integrity FE180 and circuit integrity E30, screened Measuring and control cable providing functional integrity in the event of fire. Not designed for laying in earth or water. Not UV- and water resistant. Stahování
Bezhalogenové kabely a vedení JE-H(St)H...Bd FE180/E90 or Industry electronic control cable, with insulation integrity FE180 and circuit integrity E90, screened Measuring and control cable providing functional integrity in the event of fire. Not designed for laying in earth or water. Not UV and water resistant. Stahování
Bezhalogenové kabely a vedení L-H(St)H EIB Motor power supply cable for EIB-Bus, halogen-free, screened For installation on and under plaster in dry, damp and wet locations, as a BUS cable (EIB installation bus) and as a measuring and control cable in power installations. Stahování
Holý materiál CU-Seil soft Cu rope, soft, compressed Conductors are designed for connection of points with equal electric potential or for high currents. Stahování
Holý materiál CU-Seil hard acc. 48201 CU rope hard acc. to 48201 Conductors are designed for connection of points with equal electric potential or for high currents. Stahování

Kontaktujte nás